UVP ChemStudio Series (legacy models)

plus d'images

Features

Please note: The availability of this devices is limited and will be replaced by the new devices of the redesigned ChemStudio family. In case of interest please don´t hesitate to contact us.

  • Imager for chemiluminescence, fluorescence and colorimetry
  • Upgradeable for NIR/multiplexing imaging applications
  • Selection of highly sensitive, cooled CCD cameras with fixed-focal-length or zoom lenses (motorized or manual zoom)
  • Light-tight darkrooms with large front door and unique UV-safe gel viewer window
  • Available as either a PC-operated unit or as a stand-alone instrument with an integrated color touchscreen
  • Includes Ethidium Bromide emission filter in an easy-to-access filter wheel with to up to five positions
  • Integrated overhead (epi) white light for optimum illumination and focusing
  • Chemi tray for sample placement on the black, non-reflective surface
  • Pull-out tray provides easy access to the UV transilluminators
  • Upgrade options with versatile accessories, such as multispectral light sources, overhead UV light sources, LED white light plates and much more
  • VisionWorks Software, with comprehensive features, optimizes image acquisition and analysis

Product Info

Please note: The availability of this devices is limited and will be replaced by the new devices of the redesigned ChemStudio family. In case of interest please don´t hesitate to contact us.

Highly sensitive chemiluminescence systems

The UVP ChemStudio Series has been designed for a wide range of imaging applications. Depending on system configuration, usages range from simple gel documentation to advanced, multispectral and multifunctional imaging. Significant applications include high-resolution detection of chemiluminescence, fluorescence and colorimetric samples. ChemStudio can be used to meet countless BioImaging needs, both in the fields of proteomics and genomics. When operated with VisionWorks software, automated image acquisition and analysis can be realized.
In addition to comprehensive image acquisition features, the software provides extensive and detailed image analysis tools, including 1D, area density and colony counting capabilities

  • Chemiluminescence, fluorescence and colorimetry
  • Expandable to IR/NIR multiplex applications
  • Designed with simplicity and ease-of-use in mind
  • Extensive standard equipment

A winning combination: CCD cameras and lenses
In order to meet the requirements for recording different types of signals, a set of scientific-grade, cooled CCD cameras with resolutions of up to 8.1 MP is available. The cameras are combined with a variety of high-quality lenses, either with fixed focal length or zoom function. Moreover, the integrated Peltier cooling is essential for detection of low light chemiluminescence signals, e.g. for Northern, Western and Southern Blots. When compared directly to other detection methods, cooled CCD cameras are superior in terms of sensitivity, accuracy, dynamic range, speed and ease of handling.

Image acquisition and analysis:
Simple and intuitive VisionWorks software

Chemiluminescence imaging and subsequent analysis are significantly simplified using a combination of ChemStudio systems and VisionWorksLS. VisionWorks is a modern software package with an extensive array of features to simplify the imaging of chemi-luminescence, fluorescence and colorimetric gels, blots, colonies and membranes. Once positioned on the imaging platform, the sample is focussed and the picture is captured. The full dynamic range can be acquired with the use of dynamic and sequential integration capabilities. High sensitivity and superior resolution cameras guarantee excellent, publication quality and quantifiable results.

  • Extensive imaging capabilities
  • Image enhancement functions
  • User-defined master templates for simple, 1-click image capture
  • Support for 21 CFR Part 11 compliance
  • Reporting and data export to Excel

Most combinations of camera and lens allow imaging settings to be automatically controlled. The VisionWorksLS software menu provides a variety of features to ensure high quality, repeatable image acquisition.

  • Integration: On-Chip, sequential or dynamic
  • Binning
  • Saturation preview
  • Automatic exposure

Furthermore, the software offers a substantial range of tools for detailed image analysis. These features, which are easy to use and intuitive to apply, provide the capability to automate all experiments with precise quantification. Creation of profile graphs with intensity histograms, concentration curves and much more are available with VisionWorksLS. 

  • 1D lane analysis
  • Area density analysis
  • Colony counting analysis
  • Plant imaging
  • Molecular weight standards
  • Protein quantification
  • Quantitative analysis of PCR products
  • Western Blot densitometry
  • GFP expression tracking
  • Multiplexing and more

Flexibility and modularity:
Accessories for convenient system expansion

All chemiluminescence systems can be combined with a selection of transilluminators for ethidium bromide or differently stained gels. Models are available with a single excitation wavelength of 302 nm or with multiple excitation wavelengths in the UV range. Additionally, white light converter plates and LED white light plates allow for visualization of colorimetric gels, colony plates, autoradiograms or other samples being excited by white light. Furthermore, Visi-BlueTM converter plates enable blue light excitation of samples containing GelGreen, SYBR® Green and other “safe” stains. Analytik Jena also offers overhead (epi) UV modules for an optimum image presentation of thin-layer chromatog-raphy plates.
Multiplex and fluorescence Western Blot imaging are accomplished with the external eLITE multi spectral light source. The fiber optic cables are directly connected within the darkroom to provide a brilliant, highly intense excitation of the samples. All light sources use specialized filters to meet the wavelength requirements of different dyes such as GFP, RFP, CY and IR-dyes.

  • Transilluminators and overhead (epi) UV modules
  • Multiple excitation and emission filters are available
  • White light converter plates and LED white light plates
  • Visi-BlueTM converter plates 
  • eLITE - multispectral light sources

Technical Data

Please note: The availability of this devices is limited and will be replaced by the new devices of the redesigned ChemStudio family. In case of interest please don´t hesitate to contact us.

UVP ChemStudio   

UVP ChemStudio SA2

UVP ChemStudio PLUS

Simple, efficient darkroom configuration

Stand-alone system with integrated PC and 15.6” color touchscreen

High-end darkroom for a variety of imaging applications

Cost-effective alternative to other chemiluminescence systems

Simple, intuitive software user interface

Motorized platform lift

4-position emission filter wheel

USB ports as well as wired and wireless networking capabilities
for saving images

Manually controlled illumination and emission filter wheel

5-position emission filter wheel

5-position emission
filter wheel

Camera and lens controlled manually or via software

Fully automatic control: illumination, camera, lens and emission filter wheel 

Fully automatic control: illumination, camera, lens and emission filter wheel

VisionWorks software: image acquisition and analysis

Stand-alone software: acquisition, multilingual

VisionWorks software: image analysis (requires external computer)

VisionWorks software: image acquisition
and analysis

CCD Cameras and Lenses

Application

CCD Camera 515

CCD Camera 815

CCD Camera 615

Chemiluminescence

       ++

      +++

      +++

Fluorescence

       ++

      +++

      ++

Colorimetry

       ++

      +++

      ++

NIR

       +

      ++

      +++

Multiplex

       +

      ++

      +++

Specifications

CCD Camera 515

CCD Camera 815

CCD Camera 615*

Greyscale

65,536

65,536

65,536

Bit depth

16 Bit

16 Bit

16 Bit

Pixel resolution

2336 x 1751

3296 x 2472

2184 x 1472

Megapixels

2.1
(may be expanded to 6.4)

8.1
(may be expanded to 16.2*)

3.2
(may be expanded to 9.6*)

Cooling

Room temp
– 57 °C Peltier cooling

Room temp
– 57 °C Peltier cooling

Room temp
– 60 °C Peltier cooling

Binning

1 x 1 to 8 x 8

1 x 1 to 8 x 8

1 x 1 to 10
x 10

Quantum
eff. Peak / 425 nm

50 %
and 42 %

50 %
and 42 %

88 %
and 60 %

Lenses

12.5 – 75 mm
f/1.2 Zoom lens

42.5 mm f/0.95
25 mm f/0.95

50 mm f/1.2
25 mm f/0.95

* Only for ChemStudio and ChemStudio PLUS

Analytik Jena‘s BioImaging products eliminate the need for film and accordant processing chemicals. Thus, the ChemStudio line supports eco-friendly, „Green“ imaging practices.

Order Info

Please note: The availability of this devices is limited and will be replaced by the new devices of the redesigned ChemStudio family. In case of interest please don´t hesitate to contact us.

Order number  

Description

Darkrooms

UVP ChemStudio

  • Darkroom for chemiluminescence imaging
  • Without PC and without transilluminator
  • Including epi white light, Ethidium Bromide emission filter, gel ruler and tray, focus target, Chemi tray (black)
  • VisionWorks Acquisition & Analysis (single license)

849-97-0685-04

UVP ChemStudio + 515 CCD camera + 12.5 - 75 f/1.2 manual zoom lens (230 V)

849-97-0685-05

see above (115 V)

849-97-0686-04

UVP ChemStudio + 515 CCD camera + 12.5 - 75 f/1.2 motorized zoom lens (230 V)

849-97-0686-05

see above (115 V)

849-97-0830-02

UVP ChemStudio + 815 CCD camera + 42.5 mm f/0.95 lens, manual (230 V)

849-97-0830-01

see above (115 V)

849-97-0827-02

UVP ChemStudio + 815 CCD camera + 42.5 mm f/0.95 lens, motorized (230 V)

849-97-0827-01

see above (115 V)

UVP ChemStudio SA2

  • Darkroom for chemiluminescence imaging
  • Stand alone with integrated 15.6“ color touchscreen
  • Without transilluminator
  • Including epi white light, Ethidium Bromide emission filter, gel ruler and tray, focus target, Chemi tray (black)
  • VisionWorks Acquisition & Analysis (single license, separate PC required)

849-01004-2

UVP ChemStudio SA2 + 515 CCD camera + 12.5 - 75 mm f/1.2 motorized zoom lens (230 V)

849-01005-2

UVP ChemStudio SA2 + 815 CCD camera + 42.5 mm f/0.95 motorized lens (230 V)

849-01004-4

UVP ChemStudio SA2 + 515 CCD camera + 12.5 - 75 mm f/1.2 motorized zoom lens (115 V)

849-01005-4

UVP ChemStudio SA2 + 815 CCD camera + 42.5 mm f/0.95 motorized lens (115 V)

UVP ChemStudio PLUS Automated

  • Darkroom for chemiluminescence imaging with automated platform lift
  • Without PC, without Camera/Lens Kit and without transilluminator
  • Including Ethidium Bromide, SYBR Green and SYBR Gold emissions filter, epi white light, gel ruler and tray, focus target, Chemi tray (black), LED white light plate
  • VisionWorks Acquisition & Analysis

849-97-0835-02

UVP ChemStudio PLUS motorized + 818 CCD camera + 42.5 mm f/0.95 lens, motorized (230 V)

849-97-0835-01

see above (115 V)

849-97-0714-02

UVP ChemStudio PLUS motorized + 818 CCD camera + 25 mm f/0.95 lens, motorized (230 V)

849-97-0714-01

see above (115 V)

849-97-0400-02

UVP ChemStudio PLUS motorized + 615 CCD camera + 50 mm f/1.2 lens, motorized (230 V)

849-97-0400-01

see above (115 V)

849-97-0715-02

UVP ChemStudio PLUS motorized + 615 CCD camera + 25 mm f/0.95 lens, motorized (230 V)

849-97-0715-01

see above (115 V)

Accessories

849-20600-0

Gel ruler, fluorescent (Scope of delivery of darkrooms, double pack)

849-20605-0

Gel tray, 29 x 23 cm (Scope of delivery of darkrooms)

849-20603-0

Gel cutter (Double pack)

846-057-013

Gel scooper, UV transparent, 14 x 15 cm

849-20601-0

Faceshield, UV blocking

849-20601-0

Focus target, fluorescent (Scope of delivery of darkrooms, double pack)

849-20500-0

LED white light plate (Scope of delivery of ChemStudio PLUS)

849-20501-0

Chemi tray (black), (Scope of delivery of darkrooms)

Software

849-00202-0

UVP VisionWorksLS Acquisition & Analysis

Converter plate

849-20510-0

UVP Converter UV to white, 21 x 26 cm

849-20511-0

UVP Converter UV to white, 25 x 26 cm

849-20512-0

UVP Converter UV to white, 20 x 40 cm

849-20520-0

UVP Visi-BlueTM Converter, 460 – 470 nm, 21 x 26 cm   

849-20521-0

UVP Visi-BlueTM Converter, 460 – 470  nm, 25 x 26 cm

849-20522-0

UVP Visi-BlueTM Converter, 460 – 470, 20 x 40 cm

MultiSpectral light sources

230 V
849-00300-2

100/115 V
849-00300-4

UVP eLITE Xenon, Kit with epi light fibers

230 V
849-00301-2

100/115 V
849-00301-4

UVP eLITE motorized, Kit with epi light fibers

230 V
849-00302-2

100/115 V
849-00302-4

UVP eLITE manual, Kit with epi light fibers

Emission filter

849-00400-0

Emission Filter 580 - 630 nm: Deep Purple, EtBr, RFP

849-00401-0

Emission Filter 510 - 560 nm: SYBR® Green

849-00402-0

Emission Filter 520 - 620 nm: SYBR® Gold

849-00403-0

Emission Filter 465 - 495 nm: CFP mice

849-00404-0

Emission Filter 503 - 523 nm: GFP mice

849-00405-0

Emission Filter 513 - 557 nm: Cy2®, FITC, FAMTM, GFP, SYBR® Green, SYBR® Gold

849-00406-0

Emission Filter 565 - 625 nm: Alexa555®, Cy3®, SYPRO® Orange

849-00407-0

Emission Filter 607 - 682 nm: Alexa568®, SYPRO® Red, TexasRed®

849-00408-0

Emission Filter 668 - 722 nm: Alexa633®, Cy5®

849-00409-0

Emission Filter 700 - 740 nm: IRDye 680, CF 680

849-00410-0   

Emission Filter 767 - 807 nm: Alexa750®, Cy7®

849-00411-0

Emission Filter 780 nm long pass: Alexa750®

849-00412-0

Emission Filter 800 nm long pass: IRDye 800, CF 770

Excitation filter for UVP eLITE motorized and UVP eLITE Xenon

849-00310-0

Excitation Filter 450 nm short pass: CFP, SYPRO® Ruby

849-00311-0

Excitation Filter 455 - 495 nm: Cy2®, FITC, FAM®, GFP, SYBR® Green

849-00312-0

Excitation Filter 502 - 547 nm: Deep Purple, Et Bromide, RFP

849-00313-0

Excitation Filter 533 - 587 nm: Alexa568®, Rhodomine Red, SYPRO® Red

849-00314-0

Excitation Filter 600 - 645 nm: Alexa633®, Cy5®, IRDye 680, CF 680

849-00315-0

Excitation Filter 687 - 748 nm: Alexa750®, Cy7®, IR

849-00316-0

Excitation Filter 700 - 740 nm: CF 750, IRDye 680 & 800, CF 680 & 770

849-00317-0

Excitation Filter 750 - 780 nm: IRDye 800, CF 770

Excitation filter for UVP eLITE manual

849-00330-0

Excitation Filter 450 nm short pass: CFP, SYPRO® Ruby

849-00331-0

Excitation Filter455 - 495 nm: Cy2®, FITC, FAM®, GFP, SYBR® Green

849-00332-0

Excitation Filter 502 - 547 nm: Deep Purple, Et Bromide, RFP

849-00333-0

Excitation Filter 533 - 587 nm: Alexa568®, Rhodomine Red, SYPRO® Red

849-00334-0

Excitation Filter 600 - 645 nm: Alexa633®, Cy5®, IRDye 680, CF 680

849-00335-0

Excitation Filter 687 - 748 nm: Alexa750®, Cy7®, IR   

849-00336-0

Excitation Filter 700 - 740 nm: CF 750, IRDye 680 & 800, CF 680 & 770

849-00337-0

Excitation Filter 750 - 780 nm: IRDye 800, CF 770

 

Please find a wide choice of compatible transilluminators here.

Downloads

Download on Request
(e.g. Application Notes, Software, Manual, Short Manual)

Product Inquiry

Are you interested in receiving more information about this product?

Product inquiry

The newsletter of Analytik Jena frequently keeps you posted about:

Sign up here